Search

Railways Applications

APPLICATION: HVAC EQUIPMENTModel No: NP-0713
520VA Railway DC-AC Inverter
GENERAL FEATURES:
Tree phase sinusoidal inverter without neutral and with galvanic isolation input to output for railway rolling stock application according to EN50155.
DC input voltage: 110VDC
DC input voltage range: 80 ...137VDC
Ripple <15%Vpp
Starting inrush current: 5A A 110Vdc input
Efficiency: >90%
Output voltage: 150VAC, 3Phase
Apparent power: 520VA
Shock: EN61373 Category 1 class B body mounted
Vibration: EN61373 Category 1 class B body mounted
Operating temperature range: -25°C to +45°C according Class T3 -EN50155
Dimensions: 140 x 280 x 60mm
 
APPLICATION: VIDEO ON BOARD SYSTEM MANAGEMENTModel No: NP-0670
Triple Output DC-DC Converter 150W
GENERAL FEATURES:
DC input voltage: 72VDC
DC input voltage range: 50.4 ... 154VDC
Inrush current: < 60A
Efficiency: > 85%
Output voltage: 5VDC / 3.3VDC / 12VDC
Output current: 13A / 15A / 3A
Output peak current: 16A / 18A / 12.5A
Hold up time: 10ms / 10ms /10ms
Operating temperature range: -15...80ºC
Shock: EN61373 Category 1 class B body mounted
Vibration: EN61373 Category 1 class B body mounted
Fire and smoke regulations: NFF16-101, NFF16-102
 
APPLICATION: ATP SYSTEMSModel No: NP-0649
150W DC-DC Converter 30-80Vin -72Vout
GENERAL FEATURES:
DC input voltage: 64Vdc
DC input voltage range: 30... 80Vdc (transients according to EN50155)
Inrush current: < 6.5A
Efficiency: > 85%
Output voltage: 72Vdc
Output current: 2.4A
Operating temperature range: -25...70ºC
Choke and vibrations: EN61373
 
APPLICATION: CONTROL SYSTEMS IN DIESEL LOCOMOTIVESModel No: NP-0631
2KWatts DC-DC Converter 24Vin -110Vout
GENERAL FEATURES:
DC input voltage: 24VDC
DC input voltage range: 12... 30VDC
(transients according to EN50155)
Output voltage: 110VDC
Output current: 18A
Output current with redundancy N+1: > 15A
Hold-up time: 10ms
Operating temperature range: -25...55ºC
Choke and vibrations: EN61373
 
APPLICATION: AIR CONDITIONINGModel No: NP-0530
1.2KW DC-DC Converter 110Vin – 24Vout
GENERAL FEATURES:
DC input voltage: 110VDC
DC input voltage range: 70...120VDC
(transients according to EN50155)
Output voltage: 24VDC
Output current: 50A
Operating temperature range: -20...70ºC
Choke and vibrations: EN61373
 
APPLICATION: HVAC EQUIPMENTModel No: NP-0726
3Phase 3KVA Inverter
GENERAL FEATURES:
DC input voltage range: 50...90VDC
Ripple <15%Vpp
Efficiency: > 90%
Output voltage range: 150 250VAC 3Phase
Frequency range: 16 60Hz
Maximum continuous power (Po): 1100 W
Shock and vibration: EN61373 Category 1 class B body mounted
Fire and smoke regulations: NFF16-101, NFF16-102
 
APPLICATION: AIR CONDITIONINGModel No: NP-0709
3KWatts Three Phase Inverter
GENERAL FEATURES:
DC input voltage: 24VDC / 72VDC / 110VDC (three models)
Efficiency: > 90%
Output voltage: 400VAC 3Phase (50/60Hz)
Harmonic distortion: <2%
Maximum continuous current (Io): 4.4A
Maximum peak current (Iopk): 6.6A (5s)
Operating temperature range: -25...70°C
Shock & vibration: EN61373 Category 1 class B body mounted
Dimensions: 400 x 220 x 80mm
Weight: 5.5 kg
Remote shutdown input
Remote control via RS232 or RS485
 
APPLICATION: NAVAL CIVIL AND MILITARYModel No: NP-0696
100VA DC-AC Inverter 24Vin – 115VAC , 400Hz
GENERAL FEATURES:
Input voltage: 24VDC
Input voltage margin: -20, +25%
Output voltage: 115 VAC sinusoidal
Max. output current: 0.9Arms
Output Frequency: 400 Hz ± 2 Hz
Max. output current peak: 4.5 Apk
Operational temperature: -40...75ºC
Shock and vibrations: EN61373 Cat1 class B body mounted
 
APPLICATION: HVAC EQUIPMENTModel No:NP-0728
3KVA 60/50Hz Frequency Converter Three Phase
GENERAL FEATURES:
Optimized design, according to standard EN50155, to power the compressor of a rail HVAC system.
Input voltage: 380 VAC 3-Ph square wave
modified 1/3 – 2/3
Mains voltage range: ± 10%
Mains frequency range: 47...63 Hz
Efficiency: > 95%
Output voltage: 380 VAC 3-Ph square wave
modified 1/3 – 2/3
Frequency: 5Hz ±2 %
Output power (Po): 2500W
Apparent power: 3094VA
Shock and vibration: EN61373 Category 1 class B body mounted